Residential
Homes, villas and farmhouses on borewell or municipal supply. Steady pressure on every floor, fewer pump starts.
Recommended24L, 35L or 60L
Six jobs. From homes to factories, with model recommendations.
Residential, commercial and industrial.
Homes, villas and farmhouses on borewell or municipal supply. Steady pressure on every floor, fewer pump starts.
Recommended24L, 35L or 60L
Multi-storey buildings and pressure boosting where pressure must hold when many taps open together.
Recommended35L, 60L or 100L
Boiler and heating circuits needing reliable expansion absorption and stable pressure under heat.
Recommended60L or 100L
Water heaters and closed heating loops where heated water expands. Protects relief valves, pipes and heater tanks.
Recommended24L, 35L or 60L
Drip and sprinkler irrigation, farms and landscape systems needing steady flow without pump short-cycling.
Recommended60L or 100L
Hotels, hospitals, schools and factories on continuous duty. Certified build for tenders, bulk supply available.
Recommended100L or manifolded tanks
Model suggestions are starting points. Confirm selection against the pump, pressure settings and system demand.
A pressure tank is sized so that the pump does not short-cycle. The tank has to hold enough draw-off that, between cut-in and cut-out, the pump runs long enough to cool itself and then rests long enough to do it again. Take the pump’s flow in litres per minute, the cut-in and cut-out settings on the pressure switch, and the number of outlets served. Those three numbers settle the volume.
As a starting point in the field: a 24 litre tank suits a small 0.5 HP pump on one or two outlets; 35 litre covers a 1 HP domestic pump; 60 litre handles a 1 to 1.5 HP pump feeding several bathrooms or a small booster set; and 100 litre is the choice for 2 HP and above, multi-storey boosting, or two tanks manifolded together on a large system. Confirm against the pump curve before ordering.
Set the air pre-charge about 0.2 to 0.3 bar below the pump’s cut-in pressure. A tank pre-charged to 1.9 bar (28 psi) from the factory sits correctly with most 2.0 to 2.2 bar switches, and the charge can be adjusted between 1.5 and 2.5 bar through the double O-ring valve. Pressure that sags before the pump starts, or a pump that kicks in every time a tap opens, usually means the charge has dropped. Compare the four volumes or send the pump details for a recommendation.
Three answers settle it. Pump size, pressure settings, number of outlets.
Pump HP and pressure switch settings, for example 30 and 50 psi. Number of floors and outlets. Application type, for example booster or irrigation.
Stock all four sizes. The 35L and 60L move fastest in residential and booster work. The 100L wins commercial projects. Ask about mixed pallet pricing.
Send site details and quantities. Selection and pricing follow on WhatsApp.